Basic dimensions of electrodes for physical therapy :
Model |
Backing material |
Connection type |
Size |
LW1 |
Non woven fabric |
Button type |
(48±5)×(47±5) |
LP1 |
Sponge |
Button type |
(48±5)×(47±5) |
LW2 |
Non woven fabric |
Button type |
Φ55±5 |
LP2 |
Sponge |
Button type |
Φ55±5 |
LW3 |
Non woven fabric |
Button type |
(51±5)×(40±5) |
LP3 |
Sponge |
Button type |
(51±5)×(40±5) |
LW4 |
Non woven fabric |
Button type |
(42±5)×(24±5) |
LP4 |
Sponge |
Button type |
(42±5)×(24±5) |
LW5 |
Non woven fabric |
Button type |
(40±5)×(40±5) |
LP5 |
Sponge |
Button type |
(40±5)×(40±5) |
LW6 |
Non woven fabric |
Wire type |
(40±5)×(40±5) |
LP6 |
Sponge |
Wire type |
(40±5)×(40±5) |
LW7 |
Non woven fabric |
Button type |
(50±5)×(50±5) |
LP7 |
Sponge |
Button type |
(50±5)×(50±5) |
LW8 |
Non woven fabric |
Wire type |
(50±5)×(50±5) |
LP8 |
Sponge |
Wire type |
(50±5)×(50±5) |
LW9 |
Non woven fabric |
Button type |
(40±5)×(80±5) |
LP9 |
Sponge |
Button type |
(40±5)×(80±5) |
LW10 |
Non woven fabric |
Wire type |
40±5)×(80±5) |
LP10 |
Sponge |
Wire type |
40±5)×(80±5) |
LW11 |
Non woven fabric |
Wire type |
(85±5)×(35±5) |
LW12 |
Non woven fabric |
Button type |
(85±5)×(35±5) |
LW4060-1 |
Non woven fabric |
Wire type |
(40±5)×(60±5) |
LW4060-2 |
Non woven fabric |
Button type |
(40±5)×(60±5) |
Main indicators:
1. AC impedance: the impedance of each single adhesive pair of electrode sheet shall not exceed 3K Ω.
2. Cross section area of connecting wire: the sectional area of connecting wire shall be no less than
0.05mm².
3. Wire connection fastness: the connection fastness between the wire of electrode sheet and electrode substrate is greater than 2.94N.
Usage method:
1. Clean the pasted part.
2. Connect the wire (or button) to the equipment.
3. Remove the isolation paper, paste the electrode on the used part and smooth the backing.
Matters needing attention:
1. When using, keep the skin dry at the sticking place; keep the electrode piece in close and even contact with the skin.
2. Do not stick the electrode piece on the nipple, skin wrinkles, bone nodules, scar tissue, damaged or inflamed parts of the skin.
3. People with allergic constitution and the elderly should use it with caution. If allergy is found during use, it should be torn off immediately, and the allergy should be eliminated after treatment by medical staff.
4. Sticking this product can not accept MRI examination.
5. During the treatment, the electrodes should not be placed before and after the heart.
6. If there is any problem before or during use, it is recommended to consult a doctor.
7. The product should be stored in a well ventilated room with relative humidity no more than 80%.
8. Do not unpack unless used immediately.